Industrial Plaster

Industrial Plaster

01. Production and reproduction of gypsum models (Industrial Plaster)
02. Steel casting practice
03. Alternative to wooden, steel or plastic castings
04. Other gypsum models requiring high strength, solidity or precision
05. Gypsum cases for gypsum model production (Industrial Plaster)

 

Type

Water consistency( % )

Setting time(min.)

Expansion Ratio( % )

Tensile strength
(§¸f/§²)

Compressive strength
(§¸f/§²)

Property

Initial

Final

wet

dry

wet

dry

DIASTONE MR-150

26

18

50

0.05

35

65

350

700

Blending resin
Highest compression
Good surface
Hardness

DIASTONE MR-100

30

15

50

0.05

25

50

250

500

Blending resin
High compression
High hardness

DIASTONE MR-50

30

12

45

0.05

25

50

250

500

Blending resin
High compression
High hardness

DIASTONE MR-5L

35

20

55

0.05

20

38

200

310

Blending resin
High compression
Low expansion

DIASTONE MS-L

42

25

50

0.01

15

40

200

300

Extremely lowest
expansionv

DIASTONE M-10

35

23

45

0.03

25

45

220

350

Lowest expansion
retardation of
coagulation

DIASTONE M-20

50

15

40

0.10

18

35

160

280

Easy process
Good workability

DIASTONE M-30

45

15

30

0.03

20

38

180

300

Low expansion

DIASTONE M-40

50

15

40

0.15

18

35

180

300

Abrasion resisting

01. Amount of Water to Be Mixed

Accurate measurement of the amount of water and gypsum to be mixed is one of the most important conditions for the resultant quality. Please follow the standard mixing volume that is appropriate to each type of gypsum.
According to the increase or decrease in the amount of water to be mixed, there is a corresponding change in the time for stirring or hardening and in the gypsum model's strength and solidity, etc.

02. Mold Release Agent

In case a hygroscopic model is used, there might be some difficulties in producing a model.
Please thoroughly apply Sam Woo Surface Reinforcing Agent (Ç¥¸é°­È­Á¦) to the surface of the model and impregnate the mold lubricant with it. If the model is made of steel, Vaseline or stearic acid gerotin liquid (½ºÅ׾Ƹ°»ê °Ô·ÎÄ£ ¿ë¾×) should be used instead.

03. Stirring Time

If casting is done by molding, please mix accurately measured amounts of water and gypsum and stir the mixture thoroughly to get an even consistency before putting it into the model. In addition, if casting is done by laying, let the mixture stand for a while and use it when the viscosity of the Slurry goes up.

04. Stripping

When producing a ôÈ-type model from a èê-type model, the casting-out should be done when the calorific temperature is highest. When producing a èê-type model from a ôÈ-type model, the casting-out should be done about two to three hours after the highest calorific temperature is reached.